Relay Technical Parameters

① Rated Operating Voltage: This refers to the voltage required by the relay coil for normal operation. Depending on the relay model, this may be either AC or DC voltage.

 

② DC Resistance: This refers to the DC resistance of the relay coil, which can be measured using a multimeter.

 

③ Pull-in Current: This is the minimum current required for the relay to actuate (pull in). During normal operation, the applied current must be slightly higher than the pull-in current to ensure the relay functions reliably. Furthermore, the operating voltage applied to the coil should generally not exceed 1.5 times the rated operating voltage; otherwise, an excessive current may flow, potentially burning out the coil.

 

④ Release Current: This is the maximum current at which the relay returns to its de-energized (released) state. When the current flowing through an actuated relay drops to a certain level, the relay will revert to its released state; this current value is significantly lower than the pull-in current.

 

⑤ Contact Switching Voltage and Current: These refer to the voltage and current limits that the relay contacts can handle. These values ​​determine the magnitude of voltage and current the relay is capable of controlling; they must not be exceeded during operation, as doing so can easily damage the relay contacts.