Methods For Representing Relays
In a circuit diagram, a relay coil is represented by a rectangular box; if a relay has two coils, two adjacent rectangular boxes are drawn. The letter "J"-the designated symbol for a relay-is marked either inside or beside the rectangular box. There are two ways to represent relay contacts: one is to draw them directly next to the rectangular box, which is a more intuitive method. Alternatively, depending on the circuit's connection requirements, the individual contacts can be drawn within their respective control circuits. In such cases, the same identifying letter (e.g., "J") is marked next to both the coil and its associated contacts, and the contact sets are numbered to distinguish them from one another.
Relay contacts come in three basic configurations:
(1) Normally Open (NO) / "Make" type (denoted by the letter "H"): The contacts are open when the coil is de-energized and close when the coil is energized.
(2) Normally Closed (NC) / "Break" type (denoted by the letter "D"): The contacts are closed when the coil is de-energized and open when the coil is energized.
(3) Changeover / Transfer type (denoted by the letter "Z"): This configuration consists of a set of three contacts-a moving (common) contact positioned between two stationary contacts. When the coil is de-energized, the moving contact is disconnected from one stationary contact and connected to the other. When the coil is energized, the moving contact shifts, reversing the state of the connections (opening the previously closed contact and closing the previously open one), thereby achieving a switching or "changeover" function. Such a set of contacts is known as a changeover contact.