Principles For Selecting Solenoid Valves

1. Medium Characteristics
1) Select the appropriate type of solenoid valve based on whether the medium is in a gaseous, liquid, or mixed state.
2) Ensure the valve is specified for the correct medium temperature; otherwise, the coil may burn out and the seals may degrade, significantly shortening the service life.
3) Consider the viscosity of the medium-typically, it should be below 50 cSt. If it exceeds this value, use a multi-functional solenoid valve for port sizes larger than 15 mm, or a high-viscosity solenoid valve for port sizes smaller than 15 mm.
4) If the medium is not sufficiently clean, install a back-flushing filter upstream of the solenoid valve. For low-pressure applications, a direct-acting diaphragm-type solenoid valve may be used.
5) If the medium requires unidirectional flow and backflow is prohibited, ensure the valve is designed for one-way flow.
6) The medium temperature must fall within the range permitted for the solenoid valve.


2. Pipeline Parameters
1) Select the valve port configuration and model based on the required flow direction and the pipeline connection method.
2) Determine the nominal port size (diameter) based on the flow rate and the valve's Kv value; alternatively, it may be matched to the internal diameter of the pipeline.
3) Operating Pressure Differential: For a minimum operating pressure differential of 0.04 MPa or greater, an indirect pilot-operated valve may be used. If the minimum operating pressure differential is near or equal to zero, a direct-acting or semi-direct-acting (step-direct) valve must be selected.


3. Environmental Conditions
1) The ambient temperature (maximum and minimum) must fall within the valve's permitted range.
2) In environments with high relative humidity or exposure to water droplets or rain, select a waterproof solenoid valve.
3) In environments subject to frequent vibration, jolting, or impact, choose specialized models, such as those designed for marine applications.
4) In corrosive or explosive environments, prioritize safety by selecting corrosion-resistant models.
5) If space is limited, a multi-functional solenoid valve is recommended, as it eliminates the need for a bypass line and three manual valves, while also facilitating in-line maintenance.


4. Power Supply Conditions
1) Select either an AC or DC solenoid valve based on the type of power supply available. In general, AC power is the most convenient source;
2) For voltage specifications, prioritize the use of AC 220V or DC 24V;
3) Regarding voltage fluctuations, the typical allowable range is +10% to -15% for AC and approximately ±10% for DC. If the fluctuations exceed these limits, voltage stabilization measures must be implemented;
4) Select the rated current and power consumption based on the power supply capacity. Note that the apparent power (VA) can be high during AC startup; if the power capacity is insufficient, prioritize the use of pilot-operated (indirect-acting) solenoid valves.


5. Control Precision
1) Standard solenoid valves only have two positions-open and closed. If high control precision or stable parameter regulation is required, multi-position solenoid valves should be selected;
2) Response time: Refers to the duration from the moment an electrical signal is applied or cut off until the main valve completes its operation;
3) Leakage rate: The leakage values ​​provided in product specifications typically represent standard, cost-effective grades.
 