Main Classifications Of Solenoid Valves
Direct-Acting Solenoid Valve
Principle: When energized, the solenoid coil generates an electromagnetic force that lifts the closing element off the valve seat, opening the valve. When de-energized, the electromagnetic force disappears, and a spring presses the closing element back onto the valve seat, closing the valve.
Characteristics: Capable of operating under vacuum, negative pressure, or zero-pressure conditions; however, the nominal diameter (port size) typically does not exceed 25 mm.
Step-Direct-Acting Solenoid Valve
Principle: This type combines direct-acting and pilot-operated mechanisms. When there is no pressure differential between the inlet and outlet, the electromagnetic force-upon energization-directly lifts both the small pilot valve and the main valve's closing element, opening the valve. When a sufficient pressure differential exists between the inlet and outlet, the electromagnetic force opens the pilot valve; this causes the pressure in the lower chamber of the main valve to rise while the pressure in the upper chamber drops, creating a pressure differential that pushes the main valve open. When de-energized, the pilot valve uses spring force or fluid pressure to push the closing element downward, closing the valve.
Characteristics: Reliable operation under zero pressure differential, vacuum, or high-pressure conditions; however, it requires higher power and must be installed horizontally.
Pilot-Operated Solenoid Valve
Principle: When energized, the electromagnetic force opens the pilot orifice, causing a rapid drop in pressure within the upper chamber. This creates a pressure differential-lower pressure above the closing element and higher pressure below it-which allows the fluid pressure to push the closing element upward, opening the valve. When de-energized, the spring force closes the pilot orifice; inlet pressure then flows through a bypass orifice into the upper chamber, creating a pressure differential-higher pressure above the closing element and lower pressure below it-which causes the fluid pressure to push the closing element downward, closing the valve.
Characteristics: Supports a higher upper limit for fluid pressure and allows for flexible installation (subject to customization); however, it requires a specific fluid pressure differential to function.